Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13756280

- Product Categories
- Yamatake positioner
- Siemens positioner
- ABB positioner
- Tooling KOSO positioner
- YTC valve positioner
- Fisher positioner
- Friendly Links
Information Name: | Fisher positioner dvc6010 |
Published: | 2015-04-30 |
Validity: | 90 |
Specifications: | Smart valve positioner |
Quantity: | 100.00 |
Price Description: | |
Detailed Product Description: | DVC6000 Series FISHER Locator DVC6000 Series digital valve controller is, microprocessor-based electronic communications - electricity conversion instruments. In addition to converting the current signal into a pneumatic signal that traditional functions, DVC6000 Series digital valve controller uses the HART communication protocol, it is easy to access information critical to process operation. This can be done using a Model 275 HART Communicator on-site valve or field junction box, or use a computer or a system console that everyone in the control room to carry out. Using the HART communication protocol, the control information may be integrated into a single circuit or system basis is received. DVC6000 Series digital valve controller can be used single or double acting actuators. Digital valve controller accepts feedback valve stroke and detecting pneumatic pressure air supply and actuators. This allows the instrument to diagnose not only itself, but also to diagnose valve and actuator meter is installed. This provides you with economical and effective maintenance information, maintenance of instruments and valves can be carried out only when really needed. Wiring is economical because DVC6000 Series digital valve controller with 2-wire loop-powered 4-20mA's. It can replace existing analog meter at low cost. DVC6000 Series digital valve controllers this two-wire design does not require costly separated laying power and signal lines. Features improved process control ---- two-way digital communications to provide information on the current status of the valve. You can rely on a process to make better management decisions in these real-time information. By AMSValveLink software to analyze the dynamic characteristics of the valve, you can distinguish between the need to improve the control area and maintaining high levels of system performance. Enhanced Security ---- You can check the distance from the working status of instruments and valves, and keep the process running smoothly and safely. With a HART Communicator, laptops, or workstations, in a safe area field junction boxes, wiring board or in the control room grouping can access device information. Thus, you can minimize the risk of exposure to the environment in time and avoid going near there hard to reach places. Available for configuration DVC6010: for straight-through control valve DVC6020: Rotary and long-stroke for straight-through control valve DVC6030: a longitudinal rotary control valve DVC6000 Series digital valve controllers can be installed in Fisher and other manufacturers on a rotary actuator and a slider. Product Description DVC6000 Series digital valve controller is based microprocessor converts the electrical signal into a pneumatic signal instrument of communication. In addition to the electrical signal into a pneumatic signal that traditional functions, DVC6000 Series digital valve controllers can be used HART communication protocol, easy access is crucial to the operation of information. This function can be in the vicinity of the valve or in the field junction box with the 375 Field Communicator or a personal computer in the control room console or system implementation. Utilizing HART communications protocol information can be integrated into the control system or to a single loop basis acquisition. DVC6000 Series digital valve controller can be used single or double acting actuators. Digital valve controller receives pneumatic pressure valve stroke position feedback and gas pressure and the actuator. This allows the instrument to diagnose not only itself, but also to diagnose valve and actuator which it is installed. This provides an economical and effective maintenance information for you, so when you actually need to be able to instruments and valves necessary repairs. Wiring is economical because DVC6000 Series digital valve controller with 2-wire loop-powered 4-20mA's. This set the stage for a low-cost replacement of existing analog meters. DVC6000 Series digital valve controllers 2-wire design features to avoid the high cost of laying power and signals to separate line. Products directly mounted on the valve:: Second classification and application DVC6010: applied straight stroke control valve DVC6020: Rotary and long-stroke applied straight stroke control valve DVC6030: applies to 90-degree rotating control valve remotely install the product: DVC6005 : The basic unit for 2-pipe or wall installation DVC6015: Feedback unit applies to straight travel valve DVC6025: Feedback unit applied to the rotary valve stroke and long stroke linear DVC6035: Feedback unit applied to the rotary valve 90-degree three-input. Signal Point mode: analog input signal: 4-20mA DC standard; can provide split-range capability requires a minimum voltage at the terminals of the instrument must get 10.5 volts DC for analog control, while the HART communication a minimum voltage of 11 volts DC (See guidance booklet meter) Minimum Control Current: 4.0mA minimum current without causing the microprocessor to restart: 3.5mA maximum voltage: 30 volts DC Overcurrent Protection: Input circuit limits the current to prevent internal damage Reverse polarity protection : Reverse loop current is not damaged multi-point mode: Instrument Power: 11-30 volts DC reverse polarity protection when about 8mA: Reverse loop current will not damage occurred four pneumatic signal output signal required by the implementing agencies, the largest up. 95% of the minimum range of gas pressure: 0.4bar (6psig) Maximum range: 9.5bar (140psig) five modes of action: double-acting, single acting positive-acting, single-acting reaction type six electromagnetic interference (EMI) (6). According to IEC 61326-1 (version 1.1) test, the radiation intensity in line with grade A (Industrial) and Level B (home environment) devices, according to the plant area Immunity requirements. Seven electrical rating: to provide compliance with CSA, FM, CENELC and SAA standards of proof, Intrinsically Safe, Division 2 and fireproof structure. See Hazardous area classifications sample 9.2: 001 series and 9.2: 002. According to ANSI / ISA-82.02.01-1999 (IEC610101-1 Mod) standard pollution level 2, overvoltage category III. Eight housing electrical rating: comply with NEMA 4X, CSA IEC60529, lP66. |
Admin>>>
You are the 8788 visitor
Copyright © GuangDong ICP No. 10089450, Amy Trading Co., Ltd. Shaanxi All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 8788 visitor
Copyright © GuangDong ICP No. 10089450, Amy Trading Co., Ltd. Shaanxi All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility